Phone: 603 889-5545
Hudson (Nashua) New Hampshire
CategoryTest EquipmentFunctionTest RangeInternal sizeTestTechnical capabilities
Reliability QualMark OVS4 Typhoon Temperature & Vibration (-100C to +200C and 0~100Grms) W48"xD48"xH72" Reliability/Durability testing N/A
Reliability QualMark OVS2.5 Typhoon Temperature & Vibration (-100C to +200C and 0~100Grms) W30"xD30"xH48" Reliability/Durability testing N/A
Environmental ESPEC Thermal Walk-In  Temperature (-20C to +120C) W82"xD108"xH94" Environmental GB2423.1-2001;GB/T 13543-1992;IEC 68-2-1ETS;300019-1-3/A1-1998  
Environmental ESPEC Temp and Hummidity Temperature & Hummidity (-70C to +180C and 10% to 98% rh) W36"xD36"xH36" Low/High Temp, Damp Heat: Storage/Operation GB2423.1-2001;GB/T 13543-1992;IEC 68-2-1ETS;300019-1-3/A1-1998  
Environmental Thermotron Temp and Hummidity Temperature & Hummidity (-68C to +180C and 10% to 98% rh) W36"xD36"xH36" Low/High Temp, Damp Heat: Storage/Operation GB2423.1-2001;GB/T 13543-1992;IEC 68-2-1ETS;300019-1-3/A1-1998  
Reliability Altitude and Temp Chamber Altitude / Temperature ~572mbar or 15,000 ft W24"xD24"xH24" Altitude and temp GB2423.1-2001;GB/T 13543-1992;IEC 68-2-1ETS;300019-1-3/A1-1998  
Reliability Drop test  Package drop test 30" to 84" drop hieght table size W20"xD24" H30" to 84" Environmental Package drop test GB2423.1-2001;GB/T 13543-1992;IEC 68-2-1ETS;300019-1-3/A1-1998  
EMI 10 Meter OATS Radiated Emissions 30 MHz -18 GHz 6' Turntable/3300lbs FCC A&B, CE  A2LA accredited and FCC Registered 
EMI Test Station Conducted Emissions 150 KHz - 30 MHz Single and 3 Phase FCC A&B, CE  A2LA accredited and FCC Registered 
EMC ESD Simulator ESD Up to 30 kV na EN 61000-4-2 A2LA accredited  
EMC 3 Meter anechoic chamber RFI 80 MHz - 2500 MHz  16' x 24 x 10' EN 61000-4-3 A2LA accredited
EMC Burst Tester EFT 2 kV Single phase EN 61000-4-4 A2LA accredited
EMC Surge Tester  AC Surge 4kV Single phase EN 61000-4-5 A2LA accredited 
EMC Conducted Immunity CI 3 Vrms, 10 Vrms Single phase EN 61000-4-6 A2LA accredited
EMC Helmholts Coil Magnetics 1 A/m to 400 A/m 1.5 meters  EN 61000-4-8 A2LA accredited
EMC AC Power Source Dip/Interrupt Per spec Single phase EN 61000-4-11 A2LA accredited
EMC Flicker Analyzer Flicker  Per spec Single phase EN 61000-3-2 A2LA accredited
EMC Harmonic Analyzer Harmonics Per spec Single phase EN 61000-3-2 A2LA accredited

Download out Test Capabilities Matrix:  CCTS Test Capability Matrix

Industry-Canada-logo ce-logo japan-vcci-logo bsmi logo 01

Quality facility,

Quality experience,

Quality testing.

Guaranteed!

We're just a stone's throw away in Hudson, New Hampshire

A2LA Acredited Logo The newest EMI/EMC Testing Resource in Southern New Hampshire is A2LA Accreddited !

fcc-new-logoCore Compliance Testing Services is FCC Registered and Approved...

GlobeCore Compliance Testing Services is accredited and licensed in a number of International Organizations...

Go to top